Shanxi Zhongde Dingli Group

Disposable CO2 Fracturing Tube · Disposable Series

Single use.
Zero permits.

Single-use gas expansion tubes for regulation-free rock fragmentation. Initiation in 4 milliseconds, 9 V low-voltage wiring, no detonation, no misfire, and no blasting license.

CE & ISO Certified No Blasting License Needed 4 ms Instant Response
4ms
Instant response after electrical initiation
9V
Low-voltage initiation, 2000 V+ initiator compatible
32-40mm
Tube diameters, lengths 0.35 to 2.0 m
30%+
Operating cost saving vs conventional blasting

Why switch to disposable CO2 tubes?

Contained chemical reaction, high-pressure gas expansion, and none of the blasting baggage.

Disposable CO2 gas expansion tube product
DISPOSABLE BLASTING TUBES / STORAGE & INSPECTION

Extreme Safety

No spark, no arc, no flame. Impact, friction, and static electricity cannot trigger detonation. CO2 is inert and actually suppresses combustion.

Eco-Friendly

Only CO2 is released as the primary gas, a flame retardant by nature. No toxic CO, NOx, minimal dust, and low noise.

Cost Effective

No explosive permits, no specialized storage, no professional guards. Operating costs drop 30%+ compared with blasting.

Fast & Efficient

Fracturing completes in 4 milliseconds. No misfire, no post-blast inspection, 9 V low-voltage initiation.

Directional Control

Fracturing direction is controllable, delayed initiation is supported, and energy levels adjust to rock hardness.

No License Required

Not classified as explosives. No blasting license, easy transport and storage, and no special security personnel.

Field Proof

Watch it split.

Case footage of the disposable tube cracking rock on site, in vertical 9:16 for mobile-first viewing. The same cut works on Douyin and other short-video channels.

9:16 Vertical Case Study On-Site Footage

CASE FOOTAGE · DISPOSABLE TUBE

Five steps. Then rock.

From resistance test to ventilated face.

STEP 01

Resistance Test

Measure tube resistance with the tester and confirm the value is within the standard range, tolerance ±0.5Ω.

STEP 02

Wiring

Connect tubes in series. Use 0.5 mm² copper wire for branches and 1 mm² or larger for the main line. Seal every joint.

STEP 03

Loading

Insert the tube with the lead end facing the hole bottom, leaving about 30 cm exposed. Backfill with fine gravel, then coarse.

STEP 04

Initiation

Personnel evacuate to at least 50 m. The safety officer alarms, charges the initiator to about 2000 V, and fires.

STEP 05

Ventilation

After fracturing, ventilate continuously and enter the work area only after gas detection confirms safety.

On site: tunneling single-use pipe.

Drill and blast alternative. Safe, eco-friendly, no approval needed.

Operator inserting a disposable CO2 expansion pipe into a borehole in a tunnel face
FIELD CASE / TUNNELING SINGLE-USE PIPE INSERTION

Disposable tube vs. traditional blasting.

The regulation and safety gap at a glance.

DISPOSABLE CO2 TUBE VS TRADITIONAL BLASTING
Parameter Traditional Explosives CO2 Fracturing Tube
RegulationExplosives, strict controlNot classified as explosives
Fire RiskOpen flame, sparksNo flame, no spark
Gas Explosion RiskHigh risk in gas minesCO2 inert, zero risk
MisfireRequires professional handlingNo misfire possible
Flyrock & ShockwaveSignificantMinimal flyrock, low vibration
Toxic GasesCO, NOx, SO2Primarily CO2
Permit RequiredBlasting license mandatoryNo special license
StorageSpecialized magazineStandard warehouse OK
Stone TextureMay damage integrityPreserves stone texture

32 mm and 40 mm. 0.35 to 2.0 m.

PPR tube material, 0.55 mm² pure copper wire, leads extended 15 mm. Resistance tolerance ±0.5Ω.

32 mm Diameter Series

LengthIgnition HeadsResistance (Ω)Weight
0.35 m21.7 - 2.2350 g
0.55 m22.2 - 2.7450 g
1.0 m43.8 - 4.2830 g
1.5 m74.4 - 5.71,300 g
2.0 m109.1 - 9.61,700 g

40 mm Diameter Series

LengthIgnition HeadsResistance (Ω)Weight
0.35 m21.9 - 2.2380 g
0.55 m22.2 - 2.7670 g
1.0 m55.1 - 5.61,350 g
1.5 m75.7 - 6.61,850 g
2.0 m109.1 - 9.62,630 g

Drilling Parameters Reference

Tube ModelHole Dia.Hole SpacingDrilling DepthApplication
Φ32 × 35040 mm500-700 mm700-900 mmCut / Trim hole
Φ32 × 55040 mm500-700 mm800-1,000 mmCut / Trim hole
Φ32 × 100040 mm700-1,000 mm1,300-1,500 mmCut / Perimeter
Φ32 × 150040 mm700-1,000 mm1,800-2,200 mmPerimeter hole
Φ32 × 200040 mm700-1,000 mm2,500-3,000 mmPerimeter hole
Φ40 × 100046 mm800-1,000 mm1,300-1,500 mmPerimeter hole
Φ40 × 150046 mm800-1,000 mm1,800-2,200 mmPerimeter hole
Φ40 × 200046 mm1,000-1,200 mm2,500-3,000 mmPerimeter hole

Technical highlights.

What makes the tube safe, fast, and simple.

4 ms Instant Response

On electrical initiation, the internal compound reacts within 4 milliseconds to generate a large volume of high-pressure gas.

9 V Low-Voltage Initiation

Compatible with standard high-voltage initiators (2000 V+). Simple series or series-parallel wiring, no specialized personnel.

PPR Tube Material

High-strength PPR construction with 0.55 mm² pure copper wire leads, extended 15 mm for reliable connection.

Zero Sensitivity

Certified with zero sensitivity to impact, friction, flame, and static electricity. The safest way to break rock without explosives.

Need genuine liquid-CO2 classification? Meet the #90.

A single-use metal-shell tube running the true liquid-CO2 phase-change mechanism — for sites whose rules, permits or clients require it, without any spent-tube recovery.

#90 liquid-CO2 metal tube

  • True liquid-CO2 phase change — the same mechanism class as Cardox-type systems (600–1,000× expansion, 200–300 MPa)
  • Metal shell, single use — fire, fracture, no recovery run
  • Suits high-gas seams and sites where CO2 classification matters
BEST FOR: CO2-CLASSIFIED SITES · NO RECOVERY LOGISTICS

Gas-expansion tube (32/40 mm)

  • Chemical powder generates the expanding gas — no liquid CO2, no refill station
  • 4 ms response, 9 V initiation, PPR shell, 0.35–2.0 m
  • The expanding gas is still predominantly CO2 — the difference is the source, not the name
BEST FOR: SIMPLICITY · LOWEST UPFRONT COST

Not sure which disposable technology fits your permit situation? Send the site rules and rock type — we will recommend the line and size the tube layout.

Where disposables shine.

Mining, tunneling, quarrying, and urban construction.

01

Mining

Coal mines (low-gas), metal mines, and non-metal mines. Protects ore vein texture for higher yield.

02

Underground Works

Tunnel excavation, subway construction, and water diversion culverts with minimal disturbance to surrounding rock.

03

Infrastructure

Power shaft excavation, solar panel foundations, directional fracturing, and foundation pit digging.

04

Quarrying

Dimension stone quarrying with zero damage to texture and a higher block recovery rate than blasting.

CE & ISO
Certified International quality standards
20+
Years Rock breaking expertise
50+
Countries Global export reach
100
Pieces MOQ Low order minimum, bulk discounts over 1,000

Frequently asked questions.

What buyers ask about single-use CO2 tubes.

What is a disposable CO2 fracturing tube?

A single-use sealed PPR tube containing an internal gas-generating compound and an electric match head. Initiation produces high-pressure CO2 that splits the rock from inside the borehole.

How is it different from reusable CO2 systems?

Reusable systems use recoverable steel tubes with hundreds of cycles. Disposable tubes are single-use sealed cartridges with zero recovery equipment, a lower upfront cost, and the simplest logistics.

Do I need a blasting license?

In most jurisdictions, CO2 fracturing tubes are not classified as explosives, so no blasting license, specialized storage, or security personnel are required. Confirm local rules with our team.

What is the minimum order quantity?

Orders start from 100 pieces per model, with bulk discounts above 1,000 pieces. Contact us for current pricing and lead time.

Is there a single-use option with true liquid CO2?

Yes — the #90 disposable metal tube runs the true liquid-CO2 phase-change mechanism in a single-use metal shell. It is built for sites whose rules or clients require genuine liquid-CO2 classification, but where collecting and returning spent tubes is impractical.

Can it be used in underground coal mines?

Yes. The primary gas generated is CO2, which is inert and actually suppresses combustion, making it suitable for low-gas coal mines and other sensitive underground environments.

Get Started

Ready to switch to safer rock breaking?

Tell us your rock type, hole pattern, and order volume. We will confirm tube selection and delivery, with a response within 24 hours.

Free Consultation No Obligations Response Within 24 Hours

Request a quote

One tap opens WhatsApp with your inquiry pre-filled, or reach us through the contact page.

WhatsApp: +86 198 3400 7866 / Email: allen@dlminingequipment.com